Inquiry For Liaison Service
Sector abcEducation And Research InstituteTender ValueINR 15 Lakhs
LocationHaryana - India Ref.No47460321
Closing Date17 - Feb - 2022
Purchase of various instruments - g.m counting system with end window g.m. detector specifications, counter, electronics all solid state, micro-controller based design, preset time time settable between 1 and 9999 seconds in step of 1 second or in hhmmss format, no. of runs settable between 1 to 1000, display counts 999999 time 9999 or in hhmmss format runs 1000, hv supply adjustable to 1500v (±5v), settable through feather touch keypad on front panel., data storage store and recall facility for counts data up to 1000 readings and for the plateau readings, user interface 4 keys keypad with 16x2 line lcd for displaying key function, data transfer to pc usb port, power supply, 240 v (±10%), 50 hz ac mains through 12v battery charger mechanical, dimensions 200 l x 220 d x 70 h m, weight approximately 1 kg, detector type (1.13” dia., gamma sensitivity (co60) - 50 cps/mr/hr) mounted on acrylic planchet holder with 1 meter cable with bnc connector. typical efficiency of 72314 for beta ( sr90 ) is • at 1 cm distance => approx 20% • at 2 cms distance => pprox. 11-12%", "gamma ray spectrometer , specifications, usb based 1k multichannel analyser gamma ray spectroscopy system comprising of following • pmt base voltage divider with built in preamplifier • hv supply 0 to 1200v @ 0.5 ma ripple < 30 mv • hv adjust software settable • spectroscopy amplifier 1 µ sec semi gaussian shaping with internal pz adjustment • gain setting for amplifier software settable • output 0 to 5 v unipolar semi gaussian connected internally to adc input • adc with following specifications a. 1k channel 10 bit willkinson type b. 48 mhz clock frequency c. conversion time 20 µ sec for fs input d. adc control through silab f340 micro controller via usb interface e. differential non linearity 2% f. lld setting software settable, power supply from usb port of pc/laptop • analysis software compatible with win 7/8/10 energy calibration, roi selection, area calculation, peak search and peak information, smoothening of spectrum, data storage on pc hard disk • dimensions 76 mm dia x 125 mm height cylindrical aluminum housing to plug on to detector pmt • weight approximately 1.5 kg", "nai scintillation detector , specifications, , 2” x 2” thick flat type crystal mounted on 2” dia pmt with mu metal shield, integral assembly nai(tl) detector giving resolution @ 8% for cs-137", "lead castles for scintillation detector , specifications, 40mm thick lead shield for covering nai detector part only which is to be used with gspec-usb.", "aluminium absorber set with sliding bench, specifications, seven al discs of 0.2mm, 0.6mm, 1mm, 3mm , 4.5mm , 5.5mm & 6.5 mm thicknesses", "survey meter , specifications, portable gamma radiation survey meter ( digital type) model prsm-1 includes • detector probe halogen quenched energy compensated gm tube 71210 or equivalent internally mounted measurement range 0 - 200 mr/hr , 0 – 2000 µsv/hr , cps , cpm • accuracy ± 20% of range • energy range 100 kev to 2 mev • integration time settable as 1 / 5 / 10 sec • high voltage +400 to + 900 volts at 0.1 ma internally settable • display 16 x 2 line display for dose rate indication • backlit user selectable on or off • audio proportional to incident radiation rate, user selectable on/of • audio alarm when count rate exceeds set dose rate level (mr/hr) • indications low battery, detector failure audio & display indications • battery 4 nos of ni-mh aa type duracell (20 hrs of operational life) with external battery charger", "alpha counter , specifications, para nuclear counter model pnc-alpha (standard)- • power mains operation ( 230 v, 50 hz) • display 16 x 2 lcd dot matrix display • user interface four soft touch function keys for controlling counter operation like set up, recall data, counting • counter 999999 counts (six digit) • preset time 0 – 9999 sec • h v supply 0 to +1500 v settable and hv readout on lcd • preset time 0 – 9999 sec (or hhmmss can be provided if required) • alpha probe uhf connector on front panel • data storage 1000 readings • counts data transfer to pc using usb port • data communication software, alpha probe with drawer assembly • 2” dia zns(ag) scintillator, protected with mylar sheet, mounted on 2” dia pmt required for practical (radiation physics) at chaudhary ranbir singh university.
If you are a new user, then please register, it's Free and then fill the form below.

If you are registered with us, just fill the form below, we will get back to you shortly.


All fileds marked with '*' are compulsary.
Email Id : *
Comments: *
 Login/Register
Members/Visitors Login to continue
 Email Id:
 Password:


 Forgot Password?
 Tenders by Industry
Skip Navigation Links.
Expand Non-metallic Mineral Product TendersNon-metallic Mineral Product Tenders
more  »
Tenders by Ownership
Central Government/Public Sector Tenders
Co-operatives Tenders
Corporations/ Associations/ Others Tenders
Education & Research Institutes Tenders
Joint Sector Tenders
Non classified Tenders
Private Sector Tenders
Research Institutes Tenders
State Government Tenders
Trust Tenders
 Tenders by State in India
Skip Navigation Links.